FIRST TO DIVE 9
Correct position of the deflector
18. Fit the mouthpiecel (123697) on to the casing. If it is a
Comfobite mouthpiece check that the support is at the
top. Fit the mouthpiece collar (129154) into the groove
provided. The collar lever should be underneath and
positioned on the hose side.
19. If the regulator is a Kronos Supreme, fit the lip shield
(36) over the mouthpiece and against the mouthpiece
collar.
FINAL CHECKS
1. Pressurise the regulator to 200 bar (±10 bar)
2. Check opening effort. Apply a gradual inhalation
effort. When the MP starts to fall, release the pressure
and compare the result with the limits shown in Table 5.
Checking Specifications . If the opening effort is
outside these limits consult Table 1. Troubleshooting
Guide.
3. Check depression / flow. Apply an inhalation flow of
400 l/min and check that the depression oes not exceed
15 mbar. If it exceeds this value consult Table 1.
Troubleshooting Guide.
4. Check for leaks. Connect the first stage to a cylinder
charged to 200 bar, open the valve and submerge the
assembly in a bath of water for 1 minute. Check that
there are no leaks. If there are apparent leaks,
disassemble the 2
nd
stage completely and check all
sealing surfaces and the positioning of the parts.
END OF REASSEMBLY
Note : if you have a test bench, carry out these
test before fitting the mouthpiece. Test instructions
are given in the section Final Checks.
Note: Tests 2,3 et 4 require the use of
a regulator test bench.