4 Service Manual Kronos 2nd Stage
4. The acronyms used:
LP: Low Pressure
MP: Medium Pressure
HP: High Pressure
5. Numbers in brackets indicate the part number of the
component shown on the exploded view attached.
DISASSEMBLY PROCEDURE
1. Using a screwdriver, lift the edge of the deflector
(127622) then remove it manually by sliding it along the
hose.
2. Using 2 11/16 spanners, hold the exchanger (127606)
and unscrew the swivel nut on the hose. Remove the O-
ring from the hose nipple. Take care to avoid damaging
the seal groove. Remove the O-ring from the hose
threads.
3.
4. Remove the clip (129154) and pull off the mouthpiece
(123697). On Supreme versions, remove the lip shield
(125613)
5. Unscrew the outer crown (127602). Take off the cover
(Kronos : 127614 / Kronos Supreme : 127615).
Pull back the hose
protectors and check that
there are no dents in the
crimped sleeve. The
hose should not move in
the metal sleeve. If it
does, it should be
replaced.
Note: Before commencing disassembly, consult
the exploded view to check the reference
numbers of all parts requiring replacement.
These parts should all be replaced by new parts
and should not be re-used on the pretext that
the regulator has seen little use since its
manufacture or since its last service.
Attention: Use only the special tool when
removing O-rings in order to avoid damaging the
seal recess. The slightest scratch on a sealing
surface could cause a leak. If a surface should be
damaged then this part should be replaced with a
new one. Do not use any pointed instrument or
metal tool to remove O-rings.