Aqua Lung Kronos Servisní příručka Strana 6

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 19
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 5
6 Service Manual Kronos 2nd Stage
12. Using a screwdriver (111399) unscrew the seat
(AP2033). Push the tool (116236) inside the insert and
push the seat out. Remove the O-ring (444243).
13. Left up the edge of the exhaust valve and check that the
surface is clean and free from any scratches. It should
be flexible and have a clean contour. If it is in good
condition it is not necessary to remove it and it can be
reused. If it shows any signs of deterioration it should be
removed.
END OF DISASSEMBLY
Before starting to re-assemble the regulator,
make sure that all replacement parts have
been cleaned and lubricated in accordance
with Procedure A : Cleaning and Lubricating
on page 13
.
RE-ASSEMBLY PROCEDURE
1. If the exhaust valve has been removed, pass the valve
tail through the hole in the casing (from the outside) and
pull the tail lightly into the casing. If it is a new valve, cut
off any excess length leaving about 5mm.
2. Fit a new lubricated O-ring (444243) on the
seat(AP2033). Screw the seat into the insert (127605)
with the tool (127686).
3. Fit the insert into the casing (127617) by turning it 1/4
turn anti-clockwise. Once the insert is correctly
positioned, fit a new lubricated O-ring (124706) then
screw in the exchanger (127606) using a 11/16’’
spanner.
4. Fit a new lubricated O-ring (AP2041) on the shuttle valve
(AP2036). Fit the valve seat (AP2034). Lubricate the O-
ring (AP2041) correctly.