Aqua Lung Titan LX Servisní příručka Strana 8

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 22
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 7
14. With the flat side of the casing at eye level, screw in the
adjusting knob until the lever is about 4mm below the
level of the casing edge. Now unscrew it until the lever
just shows above the edge of the casing.
15. Using a 4mm Allen key tighten the adjusting screw one
turn for Supreme models and ¾ turn for other models.
16. Fit a new lubricated O-ring on the threaded end of the
hose. Fit a new lubricated O-ring on the hose nipple.
18.
Fit the diaphragm (13) in the casing. Press all around
the edges with a finger to ensure that it is in place. Fit
the washer (14) directly in contact with the diaphragm..
19.
After tightening the diaphragm retainer (15), hold the top
of the diaphragm and gently pull it in all directions to
ensure that it is firmly in place in the housing. If not, refit
it.
20. Fit the Legend or LX purge button making sure that the
name plate is the right way up. While holding the purge
button screw the ring fully home. Tight slightly the outer
ring with the wrench( P/N 129198)
21. Checking the venturi
21.1 Place the venturi control in the “ + “ position.
21.2 Press on the purge button. The regulator should free
flow.
While the regulator is free flowing, move the control to
the “ – “ position. The free flow should stop immediately.
If it does not stop, screw the seta in 1/8 turn and try
again.
20.1
22. Turn off the air supply and purge the second stage.
Tighten nut (5) using a 11/16” torque wrench at 0.5
Manually screw the
diaphragm retainer
(15) fully home, flat
face toward the
diaphragm. Use tool
(129001) to tighten it
an additional ¼ turn.
The spring pins for the
Titan and Legend are
different in shape.
Put the regulator under
pressure. Slide tool
(129001) along the top
edge of the casing. In the
highest position the tool
should press on the
lever, causing an airflow.
In the lowest position the
2
nd
stage should not leak
air. Adjust the seat using
the tool until the
adjustment is correct.
Put at + and purge
Put at – to stop free flow
17.
Lever adjustment: Connect
the tool (122046) to the
second stage and the MP
hose to the tool. Connect
this assembly to a Legend
first stage adjusted as
follows:
Titan LX, Legend : MP = 9.5b
Titan LX Suprême, Legend
Supreme : MP = 8.5 b
Zobrazit stránku 7
1 2 3 4 5 6 7 8 9 10 11 12 13 ... 21 22

Komentáře k této Příručce

Žádné komentáře