Aqua Lung Titan LX Servisní příručka

Procházejte online nebo si stáhněte Servisní příručka pro Potápěčské ploutve Aqua Lung Titan LX. Aqua Lung Titan LX Service manual [en] Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 22
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
SERVICE MANUAL
SECOND STAGE
LX and LEGEND
Copyright ©2005 Aqualung France
Rev. 02/2005
Zobrazit stránku 0
1 2 3 4 5 6 ... 21 22

Shrnutí obsahu

Strany 1 - LX and LEGEND

SERVICE MANUAL SECOND STAGE LX and LEGEND Copyright ©2005 Aqualung France Rev. 02/2005

Strany 2

Table 1. Troubleshooting Guide SYMPTOM POSSIBLE CAUSE TREATMENT 1. MP too high 1. Refer to First stage Troubleshooting Guide 2. The va

Strany 3 - 3

FIRST TO DIVE 11 Table 2. List of Tools and Service Kits REF DESCRIPTION APPLICATION US PART NO. 116222 MP pressure gauge comp

Strany 4 - DISASSEMBLY PROCEDURE

Table 3. Recommended cleaners and lubricants LUBRICANT / CLEANER APPLICATION SOURCE Cristo-Lube MCG 111 All O-rings Aqualung, r

Strany 5 - 5

FIRST TO DIVE 13 Procedure A Cleaning and Lubricating (All Aqualung Regulators) Cleaning brass and stainless steel parts. 1. Pre-

Strany 6

Table 4. Torque values N° REFERENCE DESCRIPTION FORCE AP2031 Nut (5) 0.5 m.kg. Table 5. Checking specifications T

Strany 7 - 7

FIRST TO DIVE 15 Maintenance Notes.

Strany 8 - Put at – to stop free flow

Exploded view of Legend second stage. Exploded view of Legend Supreme second stage.

Strany 9 - FINAL CHECKS

FIRST TO DIVE 17

Strany 10

Exploded view of LX second stage.

Strany 11 - 11

FIRST TO DIVE 19 Exploded view of LX Supreme second stage.

Strany 12

Index COPYRIGHT...

Strany 13 - (All Aqualung Regulators)

Exploded view of Octopus LX second stage.

Strany 14 - Table 4. Torque values

FIRST TO DIVE 21 Exploded view of Octopus Legend second stage.

Strany 15 - Maintenance Notes

1ere Avenue – 14e rue – BP 148 06513 CARROS cedex – France  00 33.(0)4 92 08 28 88 FAX 00 33.(0)4 92 08 28 99

Strany 16

FIRST TO DIVE 3 COPYRIGHT This manual is the property of Aqualung France. Any copying, photocopying, reproduction, translation, elect

Strany 17 - 17

4. The acronyms used: LP: Low Pressure MP: Medium Pressure HP: High Pressure 5. Numbers in brackets indicate the part number of the component sho

Strany 18

FIRST TO DIVE 5 6. Turn the adjustment handwheel anti-clockwise to the end. Hold the lever (8) down against the insert (7) and pull

Strany 19 - FIRST TO DIVE 19

15. 16. If the regulator is a Legend LX Supreme, remove the lip shield (36). Remove the mouthpiece collar (29) then the mouthpiece (1

Strany 20

FIRST TO DIVE 7 6. Insert the assembled shuttle valve, notch downwards, into the insert, holding the lever at right angles to the ins

Strany 21 - 21

14. With the flat side of the casing at eye level, screw in the adjusting knob until the lever is about 4mm below the level of the casing edge. Now