Aqua Lung SEA MK Průvodce řešením problémů

Procházejte online nebo si stáhněte Průvodce řešením problémů pro Potápěčské ploutve Aqua Lung SEA MK. Aqua Lung SEA MK Troubleshooting guide Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - TECHNICAL MANUAL

REV 01/10TECHNICAL MANUALS.E.A. (Survival Egress Air) LV-2

Strany 2

10 SEA LV2 Technical Maintenance Manual21. Remove the o-rings (31 & 33) from the piston and dis-card. Insert the pin of the seat extraction too

Strany 3 - CONTENTS

115049474546445. Gently grasp the lever and remove the entire valve assembly (44-51) from the box bottom (63). It may be necessary to push in on th

Strany 4 - CHANGE RECORD

12 SEA LV2 Technical Maintenance ManualREASSEMBLY PROCEDUREFirst Stage Reassembly32333423262322CAUTION: Before proceeding, visually inspect the cyl

Strany 5 - General Conventions

13228. Thread the ll adapter port into the lower of the two HP ports. Attach a 9/16" socket to a torque wrench and tighten the ll adapter po

Strany 6 - Immersion / Leak Test

14 SEA LV2 Technical Maintenance Manual52NOTE: Before continuing, closely examine the back up ring (15). You will note that it has a at side and

Strany 7 - DISASSEMBLY PROCEDURE

1598720. When the indicator ring bottoms out, turn it slightly counterclockwise so the corners of the square shaft of the stem point towards the ce

Strany 8

16 SEA LV2 Technical Maintenance Manual3. Mate the threaded nozzle of the ll adapter into the open ll port, and turn clockwise by hand until snug

Strany 9

17Filling the SEA with compressor ll adapterNOTE: The Compressor Fill Adapter (P/N 1006-56) is not included with SEA, and must be purchased separa

Strany 10 - Second Stage Disassembly

18 SEA LV2 Technical Maintenance ManualFilling the SEA with the MRS III Mobile Rell StationThe MRS III is a self-contained Mobile Rell Station wi

Strany 11 - THIS ENDS DISASSEMBLY

195251504945feetair outlet hole4446two threadsNOTE: If the poppet bearing does not stay in place, put a small amount of Christo-Lube® on the squar

Strany 12 - REASSEMBLY PROCEDURE

2 SEA LV2 Technical Maintenance ManualCOPYRIGHT NOTICE©2010 AQUA LUNG AMERICA. S.E.A. LV2 TECHNICAL MANUAL, P/N 108448You can contact a Technical A

Strany 13 - Turn body to

20 SEA LV2 Technical Maintenance Manual12. Using a 1/4" nut driver, tighten the locknut until air starts to leak. As soon as a leak is detecte

Strany 14

2121231. Once completely dry, install cap protector (29).2. Thread the ll port plug (21) into the ll adapter port (23) until nger tight.This En

Strany 15 - Filling Procedures

22 SEA LV2 Technical Maintenance ManualUpon initial receipt of the SEA MK/LV2/HESP (here after referred to as SEA) from the OEM or storage and prior

Strany 16

23SYMPTOM POSSIBLE CAUSE TREATMENTSystem will not remain depressurized after valve is shut and second stage is purged.1. The valve seat (20) is worn

Strany 17

24 SEA LV2 Technical Maintenance ManualTable 2: Troubleshooting Guide Second StageSYMPTOM POSSIBLE CAUSE TREATMENTLeakage or free ow from the sec

Strany 18 - Second Stage Reassembly

25PART # DESCRIPTION APPLICATION108361Tool PouchSEA MK / LV2Tool holder111610Test Gauge 0-400 psiChecking medium pressure108362Soft Case, IP Test Ga

Strany 19

26 SEA LV2 Technical Maintenance ManualPART # DESCRIPTION APPLICATION820466Christo-Lube MCG III 2 oz. tube Lubrication9-AM11708 9-46661Hex Bit Tool

Strany 20

27PART # DESCRIPTION APPLICATION9-445729-443859-445923/8” & 7/16” Wrench1/2” Wrench5/8” & 9/16” WrenchMRS III9-4460512’ AdjustableWrenchMRS

Strany 21 - Immersion Test

28 SEA LV2 Technical Maintenance ManualPART # DESCRIPTION APPLICATION820467 Christo-Lube MCG III 16 oz. tubeLubrication100398HABD/SEAVise Jaw

Strany 22 - SEA MK/LV2/HESP

29Table 4: Torque SpecicationsPART # DESCRIPTION / KEY ITEM # TORQUE108312 1st Stage Body (item 36/1st stage) 25±2 ft/lbs108305 Swivel adapter (ite

Strany 23 - First Stage/Valve Assembly

3CONTENTSCopyright Notice ...

Strany 24

30 SEA LV2 Technical Maintenance ManualProcedure A: Cleaning and LubricatingCleaning Brass Parts1. Preclean in warm, soapy water* using a nylon br

Strany 25

31On-off valve assembly may be replaced with optional "no on-off" plug, part number 108367 (see key # 39 below) & part number 820015

Strany 26 - (9/16”), Bonnet (13)

32 SEA LV2 Technical Maintenance Manual Part numbers in BOLD ITALICS indicate standard overhaul replacement part.LV-2 Second Stage59606151504948474

Strany 27

33Maintenance Notes

Strany 28

©2010Aqua Lung InternationalS.E.A. LV22340 Cousteau Court • Vista, CA 92081 Phone: (760) 597-5000 • Fax: (760) 597-4900 www.aqualung.com/military

Strany 29 - Table 4: Torque Specications

4 SEA LV2 Technical Maintenance ManualCHANGE RECORDChange No. Date Title or Description Change made by001-11 10/6/11 P. 25-28 Table 3: List of Tool

Strany 30

5IntroductionThis manual provides factory prescribed procedures for the correct service and repair of the Aqua Lung SEA LV-2. It is not intended to

Strany 31 - Key # Part # Description

6 SEA LV2 Technical Maintenance ManualMedium (Over-Bottom) Pressure Test1. With the valve closed, purge the second stage to depres- surize the

Strany 32 - LV-2 Second Stage

76. Unscrew the handwheel retaining nut (7) using a notched medium at blade screwdriver. Remove the washer (8), spring (9), handwheel (10), indica

Strany 33 - Maintenance Notes

8 SEA LV2 Technical Maintenance Manual27e27f27g27b27b27g8. Remove the backup ring (15), o-ring (16), spacer (17) and washer (18) from the stem. (N

Strany 34 - S.E.A. LV2

927c27dNOTE: There is a small pin inside the adapter port. Take care not to lose the pin when the adapter port is removed.NOTE: The check valve may

Komentáře k této Příručce