FIRST TO DIVE 5
2.2 Completely unscrew the yoke nut, then the dust cap to
remove the mechanism completely. Extract the two O-
rings.
3. Disassembly of the ACD connector on the DIN version,
Remove the cap (129216). Take a DIN/yoke adapter
(Ref : 125237 ) and screw it completely home on the
DIN handwheel in order to compress the spring.
3.1 Unscrew the nose (129202) using an allen key.
3.2 Unscrew the DIN/yoke adapter. Remove the seat
(129203) and the spring (129204). Remove the 2 O-
rings on the seat (124709) and (473057)
4. Using a 7/16’ rod’, remove the shutter screw.
(127573), then remove the seal (124703)
5. Remove the
DIN hand wheel
6. Using a 26mm flat spanner, unscrew the DIN seat
(127572) then remove the seal (820016)
7. Remove the filter (A05106).
8. Using a 1/2’’ spanner remove the spring block (127562).
Remove the spring block and the spring (122244)